Hot New Products Nipple - Air Inlet – Egebjerg Detail:
Polyurethane Air Inlet
Air inlet is one of important parts of livestock ventilation system. Comparing with the general air inlet, the Polyurethane air inlet has the following advantage.
·Light weight, high hardness, then durable
·Well sealed
·Easy Installation
·Excellent ventilating and insulation effect and
Side Wall Air Inlet
SA-650
10pa |
2050m³/h |
20pa |
3536m³/h |
25pa |
4265m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
800mm*400mm |
Reserved Size |
810mm*410mm |
SA-800
10pa |
3850m³/h |
20pa |
5381m³/h |
25pa |
6532m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
1200mm*400mm |
Reserved Size |
1210mm*410mm |
SA-1200
10pa |
3850m³/h |
20pa |
5381m³/h |
25pa |
6532m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
1200mm*400mm |
Reserved Size |
1210mm*410mm |
SA-1500
10pa |
5800m³/h |
20pa |
7860m³/h |
25pa |
8750m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
1500mm*400mm |
Reserved Size |
1510mm*410mm |
TA-1200
Layers
|
Installation Size(mm)
|
Air Rate (10 pa) |
Air Rate (20 pa) |
Air Rate (25pa) |
Reserved Size(mm) |
2 |
1200*800 |
7,700 m³/h |
10,762 m³/h |
13,064 m³/h |
1200*810 |
3 |
1200*1200 |
11,550 m³/h |
16,143 m³/h |
19,596 m³/h |
1200*1210 |
4 |
1200*1600 |
15,400 m³/h |
21,524 m³/h |
26,128 m³/h |
1200*1610 |
5 |
1200*2000 |
19,250 m³/h |
26,905 m³/h |
32,660 m³/h |
1200*2010 |
TA-1500
Layers
|
Installation Size(mm)
|
Air Rate (10 pa) |
Air Rate (20 pa) |
Air Rate (25pa) |
Reserved Size(mm) |
2 |
1500*800 |
11,600 m³/h |
15,720 m³/h |
17,500 m³/h |
1510*810 |
3 |
1500*1200 |
17,400 m³/h |
23,580 m³/h |
26,250 m³/h |
1510*1210 |
4 |
1500*1600 |
23,200 m³/h |
31,440 m³/h |
35,000 m³/h |
1510*1610 |
5 |
1500*2000 |
29,000 m³/h |
39,300 m³/h |
43,750m³/h |
1510*2010 |
CA-550
10pa |
1823m³/h |
20pa |
2586m³/h |
25pa |
3060m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
550mm*450mm |
Reserved Size |
560mm*460mm |
CA-840
10pa |
1539m³/h |
20pa |
2162m³/h |
25pa |
2614m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
840mm*350mm |
Reserved Size |
850mm*360mm |
CA-840
10pa |
3078m³/h |
20pa |
4324m³/h |
25pa |
5227m³/h |
Raw Material |
Polyurethane |
Thermal Transmissivity |
0.022 W(m.k) |
Installation Size |
840mm*700mm |
Reserved Size |
850mm*710mm |
Product detail pictures:
Related Product Guide:
He drank 106 beers a night and would throw 19 opponents over the top rope: the remarkable and tormented life of Andre the Giant | Fatten Stalls
Pork Producers Prohibit Painful Pig Pens (Op-Ed) Live Science Live Science | Farrowing Cage
Our advancement depends over the highly developed devices, excellent talents and continually strengthened technology forces for Hot New Products Nipple - Air Inlet – Egebjerg, The product will supply to all over the world, such as: Kuala Lumpur , Mozambique , Jordan , Our products are exported worldwide. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices. Our mission is "to continue to earn your loyalty by dedicating our efforts to the constant improvement of our products and services in order to ensure the satisfaction of our end-users, customers, employees, suppliers and the worldwide communities in which we cooperate".
By Janet from Orlando - 2015.11.22 12:28
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
By Adelaide from New Zealand - 2015.05.15 10:52